Untitled Document
Short Form Catalog
Catalog Request


M1151-M10A PROGRAMMABLE RESOLVER DECODER 
MULTI-TURN PROGRAMMABLE RESOLVER DECODER WITH LIMITS
 

Reliable Under Extreme Environments
The M1151-MI0A combines the ruggedness of a brushless resolver and reliability of a solid-state control. The resolver can be mounted on a machine shaft in any hostile environment, such as mechanical shock, vibration, extreme humidity and temperature changes, oil mists, coolants, solvents, etc., and the programmable unit M 115 1 -M I OA can be mounted up to 2500 ft (762 in) away in a control panel. The ratiometric converter assures high-tracking-speed and high-noise-immunity.

Self- Diagnostics with Healthy Output
The M1151-MI0A is provided with an internal self-check circuit that continuously monitors if the microprocessor is not in reset, input 120 VAC power, DC power supplies, resolver cable, and output-enable circuit. In case a fault 
occurs in any one of the above critical functions, the unit goes into fault mode and a transistor output changes state from ON to OFF. For fail-safe operation, the healthy output is ON for normal operation and OFF when a fault occurs.

Built-in Motion Detector
Motion detector output is energized when the shaft is rotating in excess of 5 RPM.

Ideal Solution for Shut Height Indication
The M1151-MI0A, along with a dual-resolver, provides an ideal solution for shut-height indication. Because of absolute nature of the resolver, the position is retained even during power loss.

M1151-M10A SPECIFICATIONS

Input Power:
     AC:  120 VAC ±1 0%, 7 VA: Optional 220,240 VAC 
     DC:  11-28 VDC, 100 mA (typical) exclusive of load, for
     outputs and control input
Operating Temperature:  -10°F to +130°F (-23°C to+55°C)
Position Transducer:  AVG Automation's dual-resolver
     series, such as RL21 0.
Max. Resolution:  4096 counts/turn
Scale Factor:  automatic
Output Update Rate:  1.4 ms
Display Range:  6 digits (000.000 to 999.999)
Decimal Point:  fixed
Position Sensor:  Multi-turn (dual) resolver with gear ratio
     4, 8, 16, 32, 64, 128, or 256:1, such as AVG
     Automation's RL21 0
Resolver Cable Length:  2500 ft. (762 m) max., shielded

OUTPUTS:
     All outputs must be the some type; control inputs
     depend upon the type of outputs

Type of Outputs:  P & N
P:  PNP (sourcing) transistor:
     Logic TRUE:  Transistor ON, 1.7 V drop @ 100 mA
     Logic FALSE:  Transistor OFF, 0.2 mA leakage @ 50 V
N:  NPN (sinking) transistor:
     Logic TRUE:  Transistor ON, 1.1 V, max. @ 100 mA
     Logic FALSE:  Transistor OFF, 0.1 mA leakage @ 50 V

 

Position Output Format:  BCD 
PLS Outputs:  3 channels, I setpoint pair per channel Motion Outputs:  
     Logic TRUE:  When shaft exceeds 5 RPM 
Output Isolation:  All outputs optically isolated up to 2500V Upper- and Lower-Safety-Limits Output: 
     TRUE:  When press ram is positioned within the safe
     range (between the programmed upper- and
     lower-safety-limits) 
     FALSE:  When the press ram is positioned above or
     below the programmed upper- or lower-safety-limits
Control Inputs:  
     Program Enable, Data Transfer, Output Enable Inputs

ELECTRICAL SPECIFICATIONS:
For units with P-Type output: 
     TRUE:  10-28 VDC max. @ 13.5 mA max. 
     FALSE:  <2 V or open circuit 
For units with N-Type output: 
     TRUE:  <2 V @ 13.5 max.; or contact closure to DC
     common 
     FALSE:  10-28 VDC or open circuit 
Data Transfer Input:  Edge-triggered (i.e, data transfer on
     both rising- and falling-edges)Minimum 500 µs
     pulse-width output updates within 5 ms of transition (<1
     ms, typ.)

 

About Us | Order Catalog | Support            © 2008 Autotech Controls. All rights reserved.