| M1151-M10A SPECIFICATIONS
Input Power:
AC: 120 VAC ±1 0%, 7 VA: Optional 220,240 VAC
DC: 11-28 VDC, 100 mA (typical) exclusive of load, for
outputs and control input
Operating Temperature: -10°F to +130°F (-23°C to+55°C)
Position Transducer: AVG Automation's dual-resolver
series, such as RL21 0.
Max. Resolution: 4096 counts/turn
Scale Factor: automatic
Output Update Rate: 1.4 ms
Display Range: 6 digits (000.000 to 999.999)
Decimal Point: fixed
Position Sensor: Multi-turn (dual) resolver with gear ratio
4, 8, 16, 32, 64, 128, or 256:1, such as AVG
Automation's RL21 0
Resolver Cable Length: 2500 ft. (762 m) max., shielded
OUTPUTS:
All outputs must be the some type; control inputs
depend upon the type of outputs
Type of Outputs: P & N
P: PNP (sourcing) transistor:
Logic TRUE: Transistor ON, 1.7 V drop @ 100 mA
Logic FALSE: Transistor OFF, 0.2 mA leakage @ 50 V
N: NPN (sinking) transistor:
Logic TRUE: Transistor ON, 1.1 V, max. @ 100 mA
Logic FALSE: Transistor OFF, 0.1 mA leakage @ 50 V |
 |
Position Output Format: BCD
PLS Outputs: 3 channels, I setpoint pair per channel Motion Outputs:
Logic TRUE: When shaft exceeds 5 RPM
Output Isolation: All outputs optically isolated up to 2500V Upper- and Lower-Safety-Limits Output:
TRUE: When press ram is positioned within the safe
range (between the programmed upper- and
lower-safety-limits)
FALSE: When the press ram is positioned above or
below the programmed upper- or lower-safety-limits
Control Inputs:
Program Enable, Data Transfer, Output Enable Inputs
ELECTRICAL SPECIFICATIONS:
For units with P-Type output:
TRUE: 10-28 VDC max. @ 13.5 mA max.
FALSE: <2 V or open circuit
For units with N-Type output:
TRUE: <2 V @ 13.5 max.; or contact closure to DC
common
FALSE: 10-28 VDC or open circuit
Data Transfer Input: Edge-triggered (i.e, data transfer on
both rising- and falling-edges)Minimum 500 µs
pulse-width output updates within 5 ms of transition (<1
ms, typ.) |