Untitled Document
Short Form Catalog
Catalog Request


M8350 RESOLVER DECODER BusMODULE
 

SPECIFICATIONS

A complete functional Decoder consists of a Cradle (specific to the programmable controller type), a Decoder Module (ASY-M8350-01 0), and a Filler Module (ASY-M8250-FIL). If fault and/or motion outputs need to be directly wired to field devices, an output module (such as, ASY-M8250-XOUT) must be used in place of the filler module. Consult Autotech for specifications on output module. 
Card Location:  Uses one or two slots (any location) in an
     1/0 rack. 
PLC Communication:  Command-based communication
     using standard program controller logic. 
Power Requirements:  
Backplane:  5 VDC @ 650mA 
Customer (Input Power):  24 VDC ± 100mA 
Environment Conditions:  
Operating Temperature:  -10°F to +130ºF (-23ºC to
     +55ºC) 
Relative Humidity:
  5 to 95% non-condensing

RESOLVER INTERFACE:
Position Transducer:  Autotech's series RL 100, E7R,
     E8R, or RLI 01, RL500 or equivalent resolvers. 
Cable Length between Resolver and M8350:  2500 feet
     max, shielded. 
Resolver Cable:  Overall foil shielded, twisted pair, such as
     Autotech's cable (CBL-1 OT22-xxxx).

PROGRAMMING:
All features programmable from keypad or through
     backplane. 
Scale Factor:  Programmable from 19 to 4095 (Resolution
     20-4096 counts per turn).

 

Offset:  Programmable from 0 to scale factor value.

OUTPUTS:
RPM Format:  Binary
Fault Detector:  -TRUE (active) on power-up -FALSE if
     broken resolver wire or internal fault is detected.
Motion Detector:  -Low and high motion limits are
     programmable from 0 to 1999 RPM -motion detector is
     TRUE when the machine's RPM is within the
     programmed limits motion detector's status is available
     on the backplane.
Direction:  CW (clockwise) or CCW (counterclockwise)
     indication. On is CCW, Off is CW.

RESPONSE TIMES:
Tach Update Time:  15ms
Position, Tach and Output Status available to
     Backplane:
  Every 700 ps typical

CONTROL INPUTS:
Program Enable (PE):  PE must be TRUE for
     programming.

ELECTRICAL SPECIFICATIONS:
Optical Isolation:  2500 VAC RMS
Input Current:  3 mA typical @ 24 VDC
Logic Levels:  -TRUE: 21 to 27 VDC (not to exceed V+
     relative to V-) -FALSE:< 1 VDC

 

About Us | Order Catalog | Support            © 2008 Autotech Controls. All rights reserved.