Short Form Catalog
Catalog Request


DM2 SINGLE-TURN RESOLVER DECODER
SNAP TRACK MOUNT
Models DM2-STRAK-xxxxx and DS2-STRAK-xxxxx

  • Decoder for single twin resolver
  • Short circuit proof resolver interface
  • Broken resolver cable indication
  • PNP sourcing, NPN sinking or TTL outputs
  • Short circuit protected outputs and output shorted
    indicator (only with P & N type of outputs)

 

 

 

 

DESCRIPTION

Autotech's Single Resolver Decoder model DM2-STRAK-xxxxx is a snap track mounted single resolver decoder especially designed for OEMs.  The unit can be ordered with PNP sourcing, NPN sinking (high or low true logic), or with TTL type of outputs.  It operates from an 11-28 VDC input power.  The decoder provides complimentary quadrature phase outputs.

 

The unit has built-in diagnostics for broken resolver cable and for shorted outputs ( P and N outputs only).  Two LED indicators provide positive indication of a properly working unit.  The resolver interface is short circuit proof.

 


DM2 SNAP TRACK MOUNT SINGLE RESOLVER DECODER SPECIFICATIONS

Input Power:  11-28 VAC, 6 W
Operating Temperature:  -10 °F to +130 °F (-23 °C to +55 °C)
Position Transducer:  AVG Automation's single turn resolver such as RL100, RL101, RL500, RL501, E1R, E7R, E8R, or E9R series
Maximum Cable Length Between Resolver and DM2:  2500 ft, shielded
Output Formats:  Factory scale quadrature
Output Type:
P:  PNP sourcing:
     Logic TRUE:  Transistor ON, 1.7 V drop @ 100 mA
     Logic FALSE: Transistor OFF,0.2 mA leakage @50 VDC
N:  NPN sinking (LOW TRUE LOGIC):
     Logic TRUE:  Transistor ON, 1.1 V max @ 100 mA
     Logic FALSE: Collector open, 0.1 mA leakage @50VDC
C:  NPN sinking (HIGH TRUE LOGIC):
     Logic TRUE:  Collector open, 0.1 mA leakage @50 VDC
     Logic FALSE: 1.1 V drop @ 100 mA
T:  TTL output, 5V logic with multiplexing:
     Logic TRUE:  3.00 mA max, 2V min.
     Logic FALSE: 24.0 mA max, 0.8V max
Transparent:  Output data is continuously updated.  The data is latched for 100 +/- 10 usec within 30 usec of a transfer input.
PC Handshake:  Edge triggered (Low to high as well as high to low); 30 usec minimum strobe width; the data is stabilized within 100 usec of any triggering edge, and remains frozen until next triggering edge comes in.
Slave Systems:  Slave units must be used in conjunction with an Autotech Master Unit.  They cannot be used as stand-alone units.  Up to seven slaves may be added to one master unit.  The slave shares the position transducer with the master.