DM2 SINGLE-TURN RESOLVER
DECODER
SNAP TRACK MOUNT
Models
DM2-STRAK-xxxxx and DS2-STRAK-xxxxx
-
Decoder for single twin
resolver
-
Short circuit proof
resolver interface
-
Broken resolver cable
indication
-
PNP sourcing, NPN
sinking or TTL outputs
-
Short circuit protected
outputs and output shorted
indicator (only with P & N type of outputs)
| DESCRIPTION
Autotech's Single Resolver Decoder
model DM2-STRAK-xxxxx is a snap track mounted single resolver
decoder especially designed for OEMs. The unit can be
ordered with PNP sourcing, NPN sinking (high or low true logic),
or with TTL type of outputs. It operates from an 11-28 VDC
input power. The decoder provides complimentary quadrature
phase outputs. |
 |
The unit has built-in diagnostics
for broken resolver cable and for shorted outputs ( P and N
outputs only). Two LED indicators provide positive
indication of a properly working unit. The resolver
interface is short circuit proof.
|
DM2 SNAP TRACK MOUNT SINGLE
RESOLVER DECODER SPECIFICATIONS
Input Power:
11-28 VAC, 6 W
Operating Temperature: -10 °F to +130 °F (-23 °C
to +55 °C)
Position Transducer: AVG Automation's single turn
resolver such as RL100, RL101, RL500, RL501, E1R, E7R, E8R, or E9R
series
Maximum Cable Length Between Resolver and DM2: 2500
ft, shielded
Output Formats: Factory scale quadrature
Output Type:
P: PNP sourcing:
Logic TRUE: Transistor ON,
1.7 V drop @ 100 mA
Logic FALSE: Transistor OFF,0.2 mA
leakage @50 VDC
N: NPN sinking (LOW TRUE LOGIC):
Logic TRUE: Transistor ON,
1.1 V max @ 100 mA
Logic FALSE: Collector open, 0.1
mA leakage @50VDC
C: NPN sinking (HIGH TRUE LOGIC):
Logic TRUE: Collector open,
0.1 mA leakage @50 VDC
Logic FALSE: 1.1 V drop @ 100 mA
T: TTL output, 5V logic with multiplexing:
Logic TRUE: 3.00 mA max, 2V
min.
Logic FALSE: 24.0 mA max, 0.8V max |
 |
Transparent:
Output data is continuously updated. The data is latched for
100 +/- 10 usec within 30 usec of a transfer input.
PC Handshake: Edge triggered (Low to high as well as
high to low); 30 usec minimum strobe width; the data is stabilized
within 100 usec of any triggering edge, and remains frozen until
next triggering edge comes in.
Slave Systems: Slave units must be used in
conjunction with an Autotech Master Unit. They cannot be
used as stand-alone units. Up to seven slaves may be added
to one master unit. The slave shares the position transducer
with the master. |
|