THE DEVICENET SLAVE NETWORK
RESOLVER
THE SINGLE-TURN AND MULTI-TURN
DEVICENET NETWORK RESOLVERS
I/O
DATA EXCHANGE
Support for Strobe, Poll,
Cyclic, and Change-of-State
(COS) data exchange methods are included in the DeviceNet Network
Resolver:
-
Strobed
-- Multi-Cast message starts off the scan cycle.
Strobable slaves, such as the DeviceNet Network Resolver,
respond based on their latency.
-
Polled
-- Master interrogates each node according to the
"polling list". Polls are sent out even as
strobe responses are being received, as bandwidth allows.
-
Cyclic
-- Devices report data on a user-configured,
time-increment-basis (input or output). Cyclic data
production is considered more efficient for applications with
slowing changing analog I/O.
-
COS
-- Device reports its data only when there is a change.
This is considered more efficient, since only data changes are
transmitted. It can be used along with Poll or Strobe.
|
 |
A
DeviceNet product may behave as a Client, Server, or both. Up to
64 Node Addresses called Media Access Control Identifiers (or
"MAC IDs"), can be connected to a single DeviceNet
network and the end-to-end distances that can be accommodated are
dependent upon the speed of the network. A DeviceNet running at a
baud rate of 125 kbps can extend up to 1640 ft (500 m) while a
DeviceNet, running at a baud rate of 500 kbps, can only extend to
328 ft (100m). |
DEVICENET NETWORK RESOLVER
SPECIFICATIONS
ELECTRICAL:
Input Power:
Voltage: Unit powered by DeviceNet network
MECHANICAL:
Housing Size:
Size
25: 2.5" (63.5 mm)
Size 40: 4.0" 0 01.6 mm)
Maximum Starting Torque:
Size 25: 5 oz-in @ 77ºF (360.04 g-mm @ 25ºC)
Size 40: 8 oz-in @ 77ºF
(576.06 g-mm @ 25ºC)
Moment of Intertia: 45 gM/CM2
Maximum Slew Speed: 5000 RPM
Shaft Size:
Size 25: 3/8" (9.53 mm)
Size 40: 5/8" (15.88
mm)
Maximum Shaft Loading:
Axial: Size 25-40 Ib (18.14 kg)
Size
40--50
lb (22.68 kg)
Radial: Size 25-36 Ib (16.33 kg)
Size
40--100
lb (45.36 kg)
|
 |
Bearing
Life (revolutions):
Size 25: 2 x 10(8)
Size 40: 2 x 10(8)
Approximate Weight:
Size
25: 1 Ib (0.45 kg)
Size
40: 6 Ib (2.72 kg)
ENVIRONMENTAL:
Shock: 200 g for 11 ms
Vibration: 20 g to 2000 Hz
Temperature:
Operating: 32ºF
to +140ºF (0ºC to +60ºC)
Storage: -40ºF to + 176ºF (-40ºC to +80ºC)
Enclosure: NEMA 13
-PRELIMINARY INFORMATION
(CONTACT
FACTORY FOR FURTHER INFORMATION
AND
AVAILABILITY)
|
|