RL210-IBS INTERBUS
MULTI-TURN RESOLVER
SAC-RL210-IBS
SPECIFICATIONS
ELECTRICAL:
To maintain optical isolation between Remote In and
Remote Out,
use two different sources for VS, and VS2.
Customer Supplied Power Input (VS1):
Voltage
range: 10-30 VDC
Input
current (max.): 450 mA
InterBus Remote In Power (VS2):
Voltage
range: V10-30 VDC
Input
current (max.): 100 mA
Connectors (on rear):
InterBus
Remote In: 9-pin male connector
InterBus
Remote Out: 9-pin female connector
24
VDC input power: 6-pin male connector
MECHANICAL:
Housing size: Size 40--4.0" (101.6 mm) dia.
Max. Starting Torque:
8
oz-in @ 77º
(576
gm-cm @ 25ºC)
Moment of Inertia (gM/CM2): 45
Max. Slew Speed (rpm): 5,000
Shaft size: 5/8" (15.88 mm)
|
 |
Max.
Shaft Loading:
Axial: 50 lb. (22.68 kg)
Radial: 100 lb. (45.36
kg)
Bearing life at Max. Mfr. Spec. (Rev.): 2 x 109
Approx. Weight: 6 lb. (2.72 kg)
ENVIRONMENTAL:
Shock: 200 g for 11 msec
Vibration: 20 g to 2,000 Hz
Operating Temperature:
32 ºF to 140ºF (OºC to
60ºC)
Storage Temperature:
-40ºF to + 185ºF (-40ºC to
+85ºC)
Enclosure: NEMA 13
INTERBUS
INTERFACE:
InterBus Remote In and InterBus Remote Out 9-pin connectors
Interface Type: Remote bus
Direction of increasing counts: CW/CCW, DIP switch
selectable
Resolver Data Format: Gray Code
Data Frame: 32-bit (lower 17-bits for position)
|
|