M8250 SERIES PLS BUSMODULES
PLUG-IN PLS MODULES FOR ALLEN BRADLEY 1771 I/O, GE FANUC 9070 AND SIEMENS TI-505 PLCs.

M8251 SERIES SPECIFICATIONS 

ASY-M8251-010, ASY-MS251-F10 PLS Modules
Power Requirements:
     Rack: 5 VDC @ 650 mA
     Customer: >24 VDC @ 100 mA
Operating Temperature:
     -10°F to +130°F (-23°C to +55°C)

PROGRAMMING:
Number of PLS Setups:  8 Groups
PLS Setpoints:
     Front Panel:  160 per PLS setup (80 per group of 8
     outputs)
     Backplane: 112 per PLS setup (56 per group of 8
     outputs)
Scale Factor:  Programmable from 16-999, common to all
     PLS setups (resolution 17 to 1000 counts-per-turn)
Offset:  Programmable from 0 to scale factor value, common
     to all PLS setups
Speed Compensation:  Programmable in scale factor
     units-per-100 rpm, up to full scale factor value. Each PLS
     channel has its own speed compensation.
Motion Detector:  LOW and HIGH Motion Limits, common
     to all PLS setups. Programmable from 0-1999 RPM.
Update Time:  (Maximum Speed with 1° Resolution)
     Module:                  Time        Speed (RPM)
     ASY-M8251-010:      
1.6 ms    100
     ASY-M8251-F10:      
0.8 ms    200

RESOLVER INTERFACE:
Position Transducer:  Single-Turn Resolver, AVG
     Automation series RL100, RL101, E7R, E8R, or
     equivalent
Resolver Cable:  CBL-10T22-xxx 
     Where xxx = length in ft, 010, 020,050, and 50 ft.
     increments, e.g., 100, 150, 200 ft., etc. (3.05,6.1,15.24
     and 15.24 m increments, e.g., 30.48,45.72,60.96 m, etc.)
     Overall foil shielded, twisted pair
Cable Length between Resolver and M8251:  2500 ft.
     (762 m), max.

Maximum Resolver Shaft Speed:  2000 RPM

CONTROL INPUTS:
Electrical Specifications:  (All lnputs) 
     Optical Isolation:
  2500 V 
     Input Impedance:
  7500 ohms
Logic Levels: 
     TRUE: 
20-30 VDC; 3 mA @ 24 VDC 
     FALSE:
  0-2 VDC, or open circuit
Program Enable (PE):  When TRUE, enables setpoint
     programming

Supervisor Enable (SE):  When TRUE enables setpoint
     and setup (scale factor, offset, program number, etc.)

Output Enable (OE):  When TRUE, PLS channel outputs
     enabled (both Fault and Motion always enabled)
ModZ and Brake Inputs:
     MZ1 /B1 =  ModZ input I or Brake Input;
     MZ2/BC =  ModZ input 1 or Brake Clear;
     MZ3 = ModZ Input 3
     MZ4 = ModZ Input 4

OUTPUTS:
     An output module is required for connection to field
     devices. Consult AVG Automation's M8250 Sourcing or
     M8250 Sinking Output Module Manual (part
     MAN-M8250-POUT and MAN8250-NOUT, respective).

Fault Output:  Normally energized; de-energizes if broken
     resolver wire or M8251 internal fault is detected.

Motion Output:  Output is energized whenever resolver
     RPM is between upper and lower programmed motion
     limits.
Number of PLS Outputs:  16