M1030 Series Tonnage Monitor
» Learn mode to automatically compute reference Tonnage!!
» Built-in sensor integrity check
» Programmable Tred limits
» Programmable Over & Under limits for Die, Process & Press-Protection
» Protection from Reverse/Snap thru Tonnage
» 2 Counters, 10 Programs
M1030 Series Tonnage Monitor
» Order your Short Form Catalog Affordable Die Protection, PLS, Brake, Shut-Height & Tonnage Monitor
Detailed Specifications
Power Input: 105-135VAC, 50/60Hz. 2SW
Operating Temperature: -10° F to 130° F
Tonnage Sensors: Autotech’s SAC-MI030-SEN strain gage sensor providing 4-20 mA signal for tonnage (Existing strain gages may be used with Autotech’s SAC-MI 030-SENA amplifier)
Number of Sensors: 2
Strain gauge element: 1 m/V @400 micro-inch/inch
Sensor Mounting: Weld pad mount or drill mount
Number of Counters: 2, Total # of Hits, % of Good

CONTROL INPUTS
Electrical characteristics:
TRUE: Contact Closure to VO (term # 15 on TB5) or 11-28VDC
input
FALSE: Open or <0.8VDC input
Program Enable: Input must be TRUE to change any value
Supervisory 1 & Supervisory 2: Supervisor inputs tor access
control
Fault Reset: When TRUE, resets all faults
Position reference Input: A FALSE to TRUE transition signifies
end of a press cycle

PROGRAMMABLE LIMITS
6 limits for each installed sensor.
The limit comparisons can ho selectively disabled, except for
Positive Tonnage Press Limit.

Positive Tonnage Press Limit: Programmed in Tons for Press
Overload Protection, can not be disabled.
Negative Tonnage Press Limit: For Snap through or Reverse
tonnage protection can be disabled.
Die Protect Band: Defined by Die Protect High & Low Limits: Both limits programmed as deviation from Reference Tons. Either in Tons or in percent of reference ton value (choice is programmable); Comparison can be disabled.
Number of Reference Storage: 10
Process Trend Band: Defined by Process High A low Limits: Both Limits programmed as deviation from Process Base Tons. Either in Tons or in percent of the Base tons. Comparison can be
Disabled (Process Base Tonnage is the running average of
tonnage measured over last several cycles; number of cycles for
averaging is programmable).

OUTPUTS:
4 Field replaceable Electromechanical relay outputs; All outputs fail
safe (The NO Relay contact closed under safe conditions, and
open under fault conditions)
Relays Specifications: 120 VAC © 10 Amp Resistive, SPST

Output Relay Output Relay De-energizes if...
Positive Tonnage
Press Limit
Measured Tonnage Exceeds Positive
Tonnage Press Limit
Negative Tonnage
Press Limit
Measured Tonnage Exceeds Negative
tonnage Press 1 limit
Over Die/Process
Limit
Measured tonnage is Greater than Die
and/or Process High Limit
Under Die/Process
Limit
Measured Tonnage is Less than Die
and/or Process Low Limit

 

Home | About Us | Order Catalog | Support | Downloads

Copyright © 2014 Autotech Controls. All rights reserved. All Product names, trademarks and registered trademarks are the property of their respective manufacturers or legal holders. Autotech Controls disclaims any proprietary interest in the marks or names of others. All prices are US List prices and are subject to change without notice.