Power Input: 105-135VAC, 50/60Hz. 2SW 
                Operating Temperature: -10° F to 130° F 
                Tonnage Sensors: Autotech’s SAC-MI030-SEN strain gage sensor
                providing 4-20 mA signal for tonnage (Existing strain gages may be
                used with Autotech’s SAC-MI 030-SENA amplifier) 
                Number of Sensors: 2 
                Strain gauge element: 1 m/V @400 micro-inch/inch 
                Sensor Mounting: Weld pad mount or drill mount 
                Number of Counters: 2, Total # of Hits, % of Good 
                 
                CONTROL INPUTS 
                Electrical characteristics: 
                TRUE: Contact Closure to VO (term # 15 on TB5) or 11-28VDC 
                input 
                FALSE: Open or <0.8VDC input 
                Program Enable: Input must be TRUE to change any value 
                Supervisory 1 & Supervisory 2: Supervisor inputs tor access 
                control 
                Fault Reset: When TRUE, resets all faults 
                Position reference Input: A FALSE to TRUE transition signifies 
                end of a press cycle 
                 
                PROGRAMMABLE LIMITS 
                6 limits for each installed sensor. 
                The limit comparisons can ho selectively disabled, except for 
                Positive Tonnage Press Limit. 
                 
                Positive Tonnage Press Limit: Programmed in Tons for Press 
                Overload Protection, can not be disabled. 
                Negative Tonnage Press Limit: For Snap through or Reverse 
                tonnage protection can be disabled. 
                Die Protect Band: Defined by Die Protect High & Low Limits: Both
                limits programmed as deviation from Reference Tons. Either in
                Tons or in percent of reference ton value (choice is programmable);
                Comparison can be disabled. 
                Number of Reference Storage: 10 
                Process Trend Band: Defined by Process High A low Limits: Both
                Limits programmed as deviation from Process Base Tons. Either
                in Tons or in percent of the Base tons. Comparison can be 
                Disabled (Process Base Tonnage is the running average of 
                tonnage measured over last several cycles; number of cycles for 
                averaging is programmable). | 
              OUTPUTS: 
                4 Field replaceable Electromechanical relay outputs; All outputs fail 
                safe (The NO Relay contact closed under safe conditions, and 
                open under fault conditions) 
                Relays Specifications: 120 VAC © 10 Amp Resistive, SPST 
                
                  
                  
                  
                    
                    
                    
                      | Output Relay | 
                      Output Relay De-energizes if... | 
                       
                    
                    
                    
                      Positive Tonnage 
                        Press Limit | 
                      Measured Tonnage Exceeds Positive 
                        Tonnage Press Limit | 
                       
                    
                      Negative Tonnage 
                        Press Limit | 
                      Measured Tonnage Exceeds Negative 
                        tonnage Press 1 limit | 
                     
                    
                      Over Die/Process 
                        Limit | 
                      Measured tonnage is Greater than Die 
                        and/or Process High Limit | 
                     
                    
                      Under Die/Process 
                        Limit | 
                      Measured Tonnage is Less than Die 
                        and/or Process Low Limit | 
                     
                  
                 
                   |