THE M1920 PLS
A NEW LEVEL OF COMPACTNESS AND
MODULARITY...
YET ANOTHER MILESTONE IN "HIGHEST PROCESSING POWER AND FEATURES PER
CUBIC INCH" FROM AUTOTECH
Built-in Fault Detector
The Fault Output is normally energized when the M1920 PLS is operating normally and the resolver wiring is intact. If an internal M1920 fault is detected, or the power fails, or one or more of the resolver wires is broken or disconnected, the Fault output will de-energize. Under fault conditions all PLS outputs and the motion output will de-energize.
Built-in Tachometer and Motion Detector
The motion detector is programmed to energize a power relay output when the machine's RPM is between the motion low and high limits. The motion detector output status is indicated on the front panel.
|
ADVANCED PLS CARD
16 PLS output based upon selectable angle on / angle off or angle on /time off. All channels have their own individual leading edge and trailing edge speed compensation for those who like to tailor reaction time at different speeds for the on time and off time. There are also two Modification to Zero
(ModZ) inputs available. ModZ is used for dynamic zeroing the zero reference point of the resolver position upon input from your device. Upon external input signal, the resolver position is reset for the particular ModZ channel. Thereafter, the position is incremented as the resolver rotates forward and outputs are turned "on" and "off" at the programmed limit settings. This feature is ideal for gluing applications, where the glue-gun must be activated at a certain position after the detection of an upcoming product.
|
M1920 PLS SPECIFICATIONS
BASE UNIT-GENERAL:
Power Requirements:
120VAC± 10%, 50/60 Hz, 24VA
240VAC± 10%, 50/60 Hz, 24VA
Operating Temperature:
-10°F to +130°F (-23°C to +55°C)
Position Transducer: Single turn resolver such as RL100;
with CBL-10T22-Mxxx cable, 2,500 ft. max.
Supervisory, Brake Input and Brake Reset Inputs:
Optically isolated TRUE: Contact closure to VS-
(common) FALSE Open circuit
Motion Detector: Low & High programmable; Motion
detector output energizes when the resolver RPM is
between low and high limits.
Brake Wear Monitor: Fail Safe, Normally energized,
de-energized when press stopping time(O-9.99 sec)
exceeds programmed danger limit - 2nd caution output
energized when stopping time exceeds caution limit. Brake Input: M1920 starts brake timing when the input
becomes TRUE.
Fault Output: TRUE: No fault FALSE: Fault of broken wire
or some other internal error. |
BASIC - PLS MODULE:
Scale Factor: Desired counts per turn minus one
Programmable from 16 to 4095, common to all PLS
programs (Resolution:1 7 to 4096 counts/turn)
Offset: Programmable from 0 to Scale Factor Value,
common to all PLS programs
Speed Compensation: Programmable for first 8 channels;
each program has its own speed compensation
Scan Time: 100 to 280 Microseconds
Digital Outputs: P or N Type (Factory ordered)
N-type units:
Logic TRUE: Transistor ON, 1.0 V @ 100 mA
Logic FALSE: Transistor OFF, 0.2 mA leakage @ 50V
N-type transistor outputs:
Use with Autotech or similar
relay output chassis
P-type units:
Logic TRUE: Transistor ON, 1.7 V @ 100 mA
Logic FALSE: Transistor OFF_02 mA leakage @ 250V
P-type transistor outputs:
Use with Autotech or similar
relay output chassis
Maximum number of Programs of Setups: 100
PLS Setpoints: 20 per program
Max. 10 for channels 1-8
Max. 10 for channels 9-16
Number of Output Channels: 16, multiple dwells
ADVANCED - PLS MODULE:
(In addition to specificaitons of the Basic PLS Module)
2 Mod-Z inputs
Angle "ON" - Time "OFF" |
Page 4
|