AVG Autotech Controls

Autotech Controls HomeAbout Autotech ControlsSupportDownloadsFree CatalogsContact Autotech Controls

M8000 Resolver Decoder Input Module Specifications

ASY-M8000-Dxxxx

Customer Power Input Requirements:
     Single-Turn Models:
     ASY-M8000-D360T:  8-28 VDC, 0.14 A @28 VDC input,
     0.43 A @8 VDC
     ASY-M8000-D360,D1000,D3600: 12VDC±10%,(10.8-13.2
     VDQ, 0.4 Ampere Typical
     Multi-Turn (dual) Models:
     ASY-M8000-D6,10,-D7,10: 12VDC±10%,(10.8-13.2VDQ,
     0.6 Ampere Typical
Chassis Power Requirements:
     Single-Turn Models:  0.17 Ampere Typical
     Multi-Turn (dual) Models:  0.23 Ampere Typical
Number of Digits:
     M8000-D360,M8000-D36OT,M8000-Dl000:  3-digits
     (3/4 full word)
     M8000-D3600:  4-digits (1 full word)
     M8000-D6, 10 and M8000-D7,10:  6-Digits (11/2 full
     words)
Remote Display Bus:      BCD 5 VDC logic (TTL Level), positive TRUE Logic, for
     each digit. Compatible with AVG Automation MI 855D
     remote display.
Tachometer Update Time:
     (ASY-M8000-D36OT-Only)Varies with resolver shaft
     RPM  
     Approx. I ms @ 120 RPM, 120 ps @ 999 RPM.
     Update time = 60 -- (RPM x 512)
Front Panel Thumbwheel Offsets:
     Full-scale thumbwheel programmable.
Rotor Excitation Voltage:
     2.5 VAC at 2.5 kHz Typical
Stator Signals:
     2.5 VAC sine-cosine, typical
Ambient Temperature:
     32 to 131 °F (0 to 55 °C)
Humidity:
     5 to 95% noncondensing

Home | About Us | Support | Downloads | Free Catalogs | Contact

Copyright © 2014 Autotech Controls. All rights reserved. All Product names, trademarks and registered trademarks are the property of their respective manufacturers or legal holders. Autotech Controls disclaims any proprietary interest in the marks or names of others. All prices are US List prices and are subject to change without notice.